• Steam Boilers
  • Used Steam Boilers
  • Boiler House Ancillary Equipment
  • Hot Water Boilers
  • Burners/Dunphy Burners
Schuster 1500 kg/hr DE 12 Steam Boiler. High Pressure Packaged Steam Boiler, three-pass reverse flame Fire tube. Standard Version. Without Burner. Output 1500 kg/hr from & at 100°C. Suitable for firing on gas or oil fuels.
Model : DE 12
Type : 3-Pass Reverse Flame
Output 1500 kg/Hr F&A 100°C
Max Operating Pressure : 12.0 Bar as standard

DE12 range is a family of packaged smoke tube steam boilers, three pass reversed flame, wet back. Standard safety pressure up to 15 bar and output from 300 to 6000 kg/h. It can be operated with liquid or gaseous fuels. Every model is complete with regulations and safety accessories for automatic operation and easy commissioning. In compliance to the current laws, each steam boiler undergoes a conformity
assessment, carried out by a Notified Body. The conformance to the essential safety requirements demanded by the European Pressure Equipment Directive 2014/68/UE (PED) is guaranteed by the CE mark.
Schuster 1000 kg/hr DE 12 Steam Boiler. High Pressure Packaged Steam Boiler, three-pass reverse flame Fire tube. Standard Version. Without Burner. Output 1000 kg/hr from & at 100°C. Suitable for firing on gas or oil fuels.
Model : DE 12
Type : 3-Pass Reverse Flame
Output 1000 kg/Hr F&A 100°C
Max Operating Pressure : 12.0 Bar as standard

DE12 range is a family of packaged smoke tube steam boilers, three pass reversed flame, wet back. Standard safety pressure up to 15 bar and output from 300 to 6000 kg/h. It can be operated with liquid or gaseous fuels. Every model is complete with regulations and safety accessories for automatic operation and easy commissioning. In compliance to the current laws, each steam boiler undergoes a conformity
assessment, carried out by a Notified Body. The conformance to the essential safety requirements demanded by the European Pressure Equipment Directive 2014/68/UE (PED) is guaranteed by the CE mark.
Schuster 500 kg/hr DE 12 Steam Boiler. High Pressure Packaged Steam Boiler, three-pass reverse flame Fire tube. Standard Version. Without Burner. Output 500 kg/hr from & at 100°C. Suitable for firing on gas or oil fuels.
Model : DE 12
Type : 3-Pass Reverse Flame
Output 500 kg/Hr F&A 100°C
Max Operating Pressure : 12.0 Bar as standard

DE12 range is a family of packaged smoke tube steam boilers, three pass reversed flame, wet back. Standard safety pressure up to 15 bar and output from 300 to 6000 kg/h. It can be operated with liquid or gaseous fuels. Every model is complete with regulations and safety accessories for automatic operation and easy commissioning. In compliance to the current laws, each steam boiler undergoes a conformity
assessment, carried out by a Notified Body. The conformance to the essential safety requirements demanded by the European Pressure Equipment Directive 2014/68/UE (PED) is guaranteed by the CE mark.
Danstoker 5000 kg/hr steam boiler KB1050
Can be supplied with any options for burner, control etc.

Currently with Dunphy TL-Series Diesel Oil Burner with electronic combustion control.
Gestra Water Level Controls and modulating water level
Gestra Blowdown Controls TDS and Bottom Blowdown
Twin Feed Pumps
JUMAG DG360 Steam Boiler WITHOUT BURNER steam production up to 360 Kg/h (235kW)
JUMAG steam boiler DG360 in compact, standing modular design, EC type-tested, with CE-label, with the following characteristics:

▪ Up to 97% boiler efficiency or higher efficiency with condensing boiler technology with a second economiser (option)
▪ Completely insulated, standing water-space vaporisation system made of boiler steel (multipass through boiler, i.e. no coil)
▪ 3 to 5 pass flue gas circulation (depending on the type of boiler)
▪ Integrated maintenance-free centrifugal pump (no piston pump)
▪ Touch panel with integrated PLC and full-text operating display for menu-guided plant operation
▪ Grid form purs. to IEC 364-3, TN-S-System, 3 AC 400V/50Hz Design of boiler control purs. to DIN/EN-standards

Steam output: 360 kg/h respectively 6.0 kg/min
Thermal output: 235 kW
Operating pressure (safety-valve): 13 bar overpressure
Working pressure max.: 11 bar overpressure
Boiler warm-up time: up to 8 minutes
Power supply: 400V / 50Hz
Connected load: kW
Exhaust connection: diameter
Boiler height: mm
Boiler width: mm
Boiler depth: mm
Hight exhaust connection (middle): mm

The data above applies in connection with the associated Jumag economiser, a feed water temperature of 95°C and 6 bar working pressure.

Safety-technical equipment: Safety-valve, water-level display with 2-fold water defect safety, safety exhaust temperature and safety steam pressure limiter pursuant to DGRL 97/23/EC.

Note: Price without burner and economiser (see accessories selection) & Ex .Works Hirschberg
JUMAG DG560 Steam Boiler with single flue gas economiser, without burner
DG560 Boiler with single flue gas economiser, without burner
Danstoker Manifold
C/W High and low pressure cut out switches, Control Stat and High Limit Thermostat and also two temperature gauges for flow and return.
Danstoker Global No.13 Hot Water Boiler "LUX". maximum working pressure of 4.0 bar.
Danstoker Global No.13 Hot Water Boiler "LUX". Max continuous heat output 10000KW and maximum working pressure of 4.0 bar. CE Marked with the max flow temperature of 120c. Boiler without mountings including delivery to Ireland but not offloading.

Feel free to get in touch with our Expert team for All types of Combustion Equipment, Boiler Hire, Industrial Boiler and burner Services, and maintenance!   

Follow us on  Facebook  &  LinkedIn 


Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.